Faucet on NoviFlow¶
Introduction¶
NoviFlow provide a range of switches known to work with FAUCET.
These instructions have been tested on NS1248, NS1132, NS2116, NS2128, NS2122, NS2150, NS21100 switches, using NoviWare versions starting from NW400.5.4, running with FAUCET v1.8.14.
Compared to older versions of NoviWare and Faucet, where manual pipeline configuration was required,
it is possible to use the GenericTFM
Hardware type to make Faucet automatically program the tables
based on the needs of its current configuration.
Setup¶
Configure the CPN on the switch¶
The only configuration required in the switch is the definition of the IP and ports on which the Faucet controller must be reached. Optionally it is also possible to change the switch DPID. In this example, the server running FAUCET is 10.0.1.8; configuration for CPN interfaces is not shown.
set config controller controllergroup faucet controllerid 1 priority 1 ipaddr 10.0.1.8 port 6653 security none
set config controller controllergroup gauge controllerid 1 priority 1 ipaddr 10.0.1.8 port 6654 security none
set config switch dpid 0x1
Create faucet.yaml¶
In order to exploit the automatic pipeline configuration, the hardware specified in
faucet.yaml
must be GenericTFM
vlans:
100:
name: "test"
dps:
noviflow-1:
dp_id: 0x1
hardware: "GenericTFM"
interfaces:
1:
native_vlan: 100
2:
native_vlan: 100
etc...
Run FAUCET¶
faucet --verbose
Using Older Faucet and NoviWare versions¶
Before the introduction of GenericTFM, Faucet used a static pipeline which needed to be configured in the switch before connecting to the controller. The following match configuration is known to pass the unit tests using NW400.4.3 with FAUCET 1.6.18, but take care to adjust ACL tables matches based on the type of ACL rules defined in the configuration file. Different FAUCET releases may also use different match fields in the other tables.
set config pipeline tablesizes 1524 1024 1024 5000 3000 1024 1024 5000 1024 tablewidths 80 40 40 40 40 40 40 40 40
set config table tableid 0 matchfields 0 3 4 5 6 10 11 12 13 14 23 29 31
set config table tableid 1 matchfields 0 3 4 5 6
set config table tableid 2 matchfields 0 5 6 10 11 12 14
set config table tableid 3 matchfields 0 3 4 5 6 10
set config table tableid 4 matchfields 5 6 12
set config table tableid 5 matchfields 5 6 27
set config table tableid 6 matchfields 3 5 10 23 29
set config table tableid 7 matchfields 3 6
set config table tableid 8 matchfields 0 3 6
Note that this table configuration will allow most of the automated test cases to pass, except FaucetIPv6TupleTest (which requires IPv6 Src and Dst matching in the ACL table). In order to run this test, table 0 must be configured as follows:
set config table tableid 0 matchfields 0 5 6 10 26 27 13 14